Skip to content

Scenarios · logistics

Warehouse Intercom Systems — paging, dock calls and radio on one site system

A warehouse is a building where nobody stands still and nothing is quiet. The communications requirement is therefore not a desk phone but coverage: announcements that cut through a working aisle, a call button at a dock door, a radio in a forklift and a handset in the gatehouse — all on one system. The design on this page builds that from SIP speakers, a radio-over-IP gateway, outdoor stations and portable handsets, registered to the same PBX that carries the office phones. NEXVIA designs, manufactures, supplies and commissions the system; the terminals are manufactured by NEXVIA.

  • Horn coverage where it is loud: the A233 is an IP66 horn with 30 W rated output and a built-in microphone for self-test and monitoring
  • Indoor aisles and offices on the same system: A212 wall speakers publish 8 Ω with up to 15 W class D output and talkback (PoE 8 W / PoE+ 15 W)
  • Up to 20 multicast zones with prioritisation, so an announcement reaches the loading dock without reaching the offices
  • The existing radio fleet stays: the W712 integrates a UHF 400–470 MHz radio module and puts one analog or DMR II radio on the same system as SIP calls
  • Dock and gate calls are extensions, not bells: the A12V is IP66 and IK10 from −40 °C to 70 °C with 2 short-circuit inputs and 2 outputs
  • Staff and drivers on the move carry Wi-Fi 6 handsets with a push-to-talk key and 16 DSS keys (W611W / W620W)
Worker at an industrial workstation beside a communications terminal

The short answer

A distribution warehouse usually lands at 4 to 40 speaker positions, 2 to 4 call stations and 4 to 20 portable handsets, behind one PBX with 62 SIP trunks on the OM50G or 496 on the OM200G. The speaker count is driven by the number of zones, not the floor area: a shipping office, a picking area, a loading bank and a yard are four zones before any aisle coverage is added.

Two numbers decide the audio design. The A233 horn publishes 30 W rated output at IP66 for the yard and the loading bank; the A212 wall speaker publishes 8 Ω with up to 15 W class D output, PoE 8 W / PoE+ 15 W and talkback for indoor areas where a two-way call is needed. Both sit in a family that supports up to 20 multicast zones with prioritisation, addressed from a console or an IP phone.

The radio fleet is the part most sites already own. The W712 gateway integrates a UHF 400–470 MHz radio module, supports one analog or DMR II radio plus one SIP call, and connects group calls between radios and SIP phones; the A201 ceiling speaker carries an offline timed broadcast, and its rated output is printed two ways in the source material, so its wattage is confirmed on the quotation. Prices are not published on this site — NEXVIA quotes per zone count, door count and cable route.

Paging architecture: the deployment tiers, and how zones and endpoints attach to them
Paging architecture: the deployment tiers, and how zones and endpoints attach to them

What goes wrong on this type of site

Nobody can hear a ring tone in an aisle

Ambient machinery noise defeats a telephone bell. The documented answers are horn and wall speakers with published output figures, up to 20 multicast zones with prioritisation, environmental noise detection, and portable handsets that vibrate and ring on the person rather than the building.

The radio fleet is not going away

Forklift and yard teams are already equipped with radios, and the radios work. The W712 keeps them: one analog or DMR II radio plus one SIP call, group calls across radios and phones, and call recording to a TF card up to 128 GB.

Dock doors, barriers and shutters

A dock call usually has to end by opening something. The door stations and consoles carry the contacts for it — A12V has 2 short-circuit inputs and 2 outputs, A10W has one relay, and the A330i console has 8 inputs, 1 output and an RS-485 interface — so the release is designed with the call rather than afterwards.

An unattended yard at night

Car parks and yards are named as unattended-site environments in the material. Anti-tamper alarms on the A12V report to the control centre if a cover is removed, the A513W combines an IP66 speaker with a 4 MP IR camera and relay contacts for a strobe, and ONVIF links the call to a VMS.

Choosing by size

Size bandSystemDevicesNotes
Single unit or small store — up to 2,000 m²OM20G — 24 SIP trunks; 4 analog ports for a legacy line4–8 speakers (A212 wall / A201 ceiling), 1–2 call stations (A10W / A12V), 2–4 wall handsets (V60G), 4–8 portable handsetsThe desktop chassis suits a single-cabinet installation. The OM20G is the only model that can dial out through a 3G/4G USB modem, which matters at a detached site with no wired line.
Distribution centre — 2,000 to 10,000 m², 4 to 10 zonesOM50G — 62 SIP trunks; up to 12 analog ports across 3 interface cards12–24 speakers across 4–10 zones, 2–4 outdoor stations, 1 console (X210i / A330i), 8–15 portable handsets, 1–2 paging gatewaysRing groups hold up to 40 extensions on this model, so a dock call group that rings the shipping office, the gatehouse and a handset fits comfortably.
Large or multi-hall site — 10,000 m² and aboveOM200G — 496 SIP trunks; up to 96 analog ports on 24-line interface cardsSpeakers per zone across halls and yard, consoles at the site office and the security desk, radio gateway for the forklift fleet, handsets per shift4 hot-swap card slots, gigabit Ethernet and single or dual AC/DC power. Up to 32 departments for group pickup and up to 60 extensions in a ring group at this size.
Multi-site logistics networkOM1000-UC — 1000 SIP trunks, up to 200 concurrent calls per trunkThe per-site counts repeated, one shared dial plan, extension ranges per site, DID numbers for shared site numbersSIP only, with dual hot standby (3 fixed IP addresses) and multi-site networking using unique or repeatable extension numbering.
Existing radio fleet that must keep workingOM50G or OM200G — 62 or 496 SIP trunksW712 RoIP gateway per radio channel, with a channel per talk group; the same speakers and handsets as aboveThe W712 integrates a UHF 400–470 MHz radio module and supports one analog or DMR II radio plus one SIP call, with group calls between radios and SIP phones. Record the radio make and model during the survey.
Retrofit where cable is scarceOM50G — 62 SIP trunksPA3 or PA2S gateways driving the existing speaker line, new SIP speakers added zone by zoneThe IP endpoint tier is stated to bridge legacy paging into the IP environment; where no data cable exists either, PN1 carries network and power over an existing two-core pair, up to 1600 m for the network function without power.

Numbers behind the design

Warehouse and logistics communications equipment, as published
ModelWhere it goesPublished capabilityPower and rating
A233Yard, loading bank, external wallsHorn speaker with 30 W rated output and a built-in microphone for system self-test, monitoring, environmental noise detection and two-way voiceIP66; PoE, PoE+ or DC
A212Picking aisles, packing, shipping office walls8 Ω with up to 15 W class D output; talkback through an omnidirectional microphone; alarm linkage; offline timed broadcast; up to 20 multicast zones with prioritisation10/100 Mbps Ethernet with integrated PoE (published as PoE 8 W / PoE+ 15 W); wall mount with optional angle bracket
A201Ceiling coverage in halls and officesCeiling SIP speaker with a built-in microphone, system self-test, monitoring, two-way voice, offline timed broadcast and up to 20 multicast zonesPoE, PoE+ or DC; the rated output is printed two ways in the source, so the wattage is confirmed on the quotation
A513WUnattended dock, gate or yard positionAll-in-one SIP speaker with a built-in 4 MP HD camera with IR night vision, H.264, built-in microphones, relay in and out for a PIR sensor, infrared sensor or strobe lightIP66; PoE or DC; dual-band 2.4G/5G Wi-Fi and BLE; up to 10 W (DC supply)
PA2SBridging an existing speaker lineSIP intercom and paging gateway: 10–30 W mono output adapting to input voltage, line out for an external active speaker, 1 short-circuit in and 1 out with a built-in relay, SOS call keyPoE to IEEE 802.3af, or 12–24 V 2 A DC; −30 °C to 60 °C
PA3Larger legacy paging system and scheduled audioSIP paging gateway: 10–30 W mono output, line out, SOS call key, line in 3.5 mm, USB 2.0 and TF card, analog output to passive speakers or amplifiers, video linkage with an IP cameraPoE / PoE+ (IEEE 802.3at, published as PoE Class 4) or 12–24 V 2 A DC; −20 °C to 50 °C
A12VGate, dock door, external help point4 MP camera with IR night vision; 10W speaker with AEC; 2 short-circuit inputs and 2 outputs; anti-tamper alarm reported to the control centreIP66 and IK10, −40 °C to 70 °C; ONVIF and RTSP on the video model
A10WInternal dock door, muster point, office doorThree function keys; 2W speaker with echo cancellation; one alarm input for an external emergency button; one-click call rings the host plus the call groupStandard 86 box; PoE or 12 V DC; IP54; −10 °C to 50 °C
W712Radio room or rack, one per radio channelRoIP gateway integrating a UHF 400–470 MHz radio module; one analog or DMR II radio plus one SIP call; group calls between radios and SIP phones; recording to a TF card up to 128 GB or USBNetwork plus UHF radio; web deployment and management; SIP standard protocol
W611W / W620WStock pickers, marshals, drivers16 DSS keys plus a configurable push-to-talk key. W611W: IP67, 1900 mAh, up to 9 h talk / 200 h standby. W620W: 3000 mAh, up to 13 h / 240 h, dual microphones and H.264 video previewWi-Fi 6 dual-band 2.4G and 5G; Bluetooth 5.0; drop-safe from 1.8 m (W611W)
V60GGatehouse, plant room, goods officeWall-mount handset with a 2.4-inch 320×240 colour screen, 6 keys and dual Gigabit portsPoE support; wall-mount only
This design against a separate paging amplifier and telephone system
RequirementSeparate paging amplifier and telephone systemThis IP designWhat changes operationally
Zone controlMechanical zone selector switches on the amplifier, one position per circuitUp to 20 multicast zones with prioritisation, addressed from a console or an IP phone; dynamic zone control and remote volume adjustment in the advanced tierAny combination of areas can be addressed from a screen instead of a switch bank
Scheduled messagesA timer unit wired into the amplifier, or a manual clockScheduled broadcasting with custom time templates, plus offline timed broadcast held on the A201 and A212 speakersThe timetable is a configuration and survives a network interruption
Dock and gate callsA bell or a telephone that nobody can see from the dockA12V and A10W stations are SIP extensions in the site call group, with relays to release a door or barrierA dock call is answered, transferred and logged like any other call
Forklift and yard staffA separate radio system with no connection to the telephoneW712 puts one analog or DMR II radio on the same system as SIP calls, with group calls between radios and phonesOne system carries both fleets, and radio traffic can be recorded with calls
Existing speaker cablingReplace the amplifier and the whole line togetherPA3 and PA2S gateways drive passive speakers and legacy analog horn speakers; the IP endpoint tier is stated to bridge legacy paging into the IP environmentThe changeover can be done zone by zone within a shutdown window
RecordsNone, or a separate logger on the telephone onlyAudio archiving of SIP paging, intercom and calls where the paging tier provides it; call detail records to a server on port 1809; radio and SIP call recording on the W712Announcements, calls and radio traffic can be reviewed after an incident
Safety alarm pathA dedicated alarm bell, unconnected to anything elseOne-key alarm activation, alarm light flashing and simultaneous calling to the management unit; short-circuit inputs take alarm buttons and sensors; A513W carries relay in and out for a strobe lightThe alarm and the announcement share one system, with priority designed in

Deployment by area

AreaDeviceNote
Yard, loading bank and external wallsA233 horn speakerIP66 horn with 30 W rated output, a built-in microphone for system self-test, monitoring, environmental noise detection and two-way voice; part of a family supporting up to 20 multicast zones with prioritisation.
Picking aisles, packing and shippingA212 wall speaker8 Ω with up to 15 W class D output and talkback through an omnidirectional microphone, with alarm linkage and offline timed broadcast; PoE 8 W / PoE+ 15 W, wall mount with an optional angle bracket.
Halls, offices and canteen ceilingsA201 ceiling speakerCeiling SIP speaker with a built-in microphone, two-way voice, self-test, monitoring and offline timed broadcast on PoE, PoE+ or DC. The rated output is printed two ways in the source, so the wattage is confirmed on the quotation.
Dock door, gate and unattended yard positionA12V outdoor intercom (A513W where camera and speaker must share one enclosure)A12V: IP66 and IK10 from −40 °C to 70 °C, 4 MP camera, 10W speaker with AEC, 2 short-circuit inputs and 2 outputs. A513W: IP66, 4 MP IR camera, up to 10 W (DC), relay in and out for a PIR sensor, infrared sensor or strobe light.
Internal dock doors and muster pointsA10W SIP mini intercomStandard 86 box with three function keys, a 2W speaker with echo cancellation, one relay and one alarm input for an external emergency button; one-click call rings the host plus the call group.
Gatehouse, goods office and plant roomsV60G wall handset (X3U at a desk position)V60G is wall-mount only with a 2.4-inch 320×240 colour screen, 6 DSS keys and dual Gigabit ports; X3U adds six lines with three LED line keys, Gigabit PoE and IPv6 for a staffed desk.
Forklift and yard radio fleetsW712 RoIP gateway, with W611W / W620W handsets for Wi-Fi coverageW712 integrates a UHF 400–470 MHz radio module and supports one analog or DMR II radio plus one SIP call with group calls between them. Handsets add 16 DSS keys and a push-to-talk key over Wi-Fi 6.

Questions buyers ask

How many speakers does a warehouse need?

Count zones, then positions within each zone. A distribution centre usually lands at 4 to 10 zones — shipping office, picking, packing, loading bank, yard, canteen, gatehouse — and 12 to 24 speaker positions behind them.

  • Outdoor zones take a horn: the A233 publishes 30 W rated output at IP66 for the yard and loading bank.
  • Indoor zones take the A212 wall speaker (up to 15 W class D, talkback, PoE 8 W / PoE+ 15 W) or the A201 ceiling speaker, whose wattage is printed two ways in the source and is confirmed on the quotation.
  • Up to 20 multicast zones with prioritisation is the design ceiling for the speaker family, so a site with more areas groups them into zones rather than adding systems.
  • Each zone should be its own run so it can be addressed and volume-adjusted independently; ambient noise detection is published on the range to help with level setting.

Can one announcement reach the yard but not the offices?

Yes. Zones are managed from the console, the speaker family supports up to 20 multicast zones with prioritisation, and the advanced tier adds dynamic zone control and remote volume adjustment per device.

  • Emergency and routine announcements are separated by priority, and one-key alarm activation with alarm light flashing is stated for the IP endpoint tier.
  • A schedule can drive routine messages without an operator: custom time templates, plus offline timed broadcast on the A201 and A212.
  • Text-to-speech lets a typed message be broadcast when nobody wants to record one.

Do we have to replace our existing paging amplifier and horn line?

No. The IP endpoint tier is stated to bridge legacy paging systems into the IP environment, and the PA3 and PA2S gateways drive passive speakers and legacy analog horn speakers — PA3 publishes 10–30 W mono output with a line out for an external amplifier, and PA2S the same output range with a built-in relay.

  • Convert the busiest zones first: the yard and the loading bank are the ones that matter most.
  • PA3 adds a line in, USB 2.0 and TF storage, and can link to an IP camera; PA2S stays compact with an SOS call key.
  • Where the old cabling is not even data-capable, PN1 puts network and power over a two-core pair up to 1600 m for the network function without power.

How do forklift drivers and marshals get a call?

Two documented routes. Staff who stay inside the Wi-Fi coverage carry a W611W or W620W handset with 16 DSS keys and a configurable push-to-talk key; where the site runs UHF radios, the W712 gateway puts one analog or DMR II radio on the same system as the SIP phones.

  • W611W is IP67 with a 1900 mAh battery (up to 9 h talk / 200 h standby) and a 1.8 m drop rating; W620W has a 3000 mAh battery (up to 13 h / 240 h), dual microphones and H.264 video preview.
  • Group calls between radios and SIP phones are the documented behaviour of the W712, which is what lets a yard radio talk to the gatehouse phone.
  • Radio coverage is a survey item: walk the site with the radio in hand before fixing the number of gateways or access points.

Can we take calls at the dock door?

Yes, and it is an extension rather than a bell. The A12V is IP66 and IK10 from −40 °C to 70 °C with a 4 MP camera, a 10W speaker with echo cancellation and 2 short-circuit inputs and 2 outputs — enough to talk to the driver and release a barrier or shutter during the call.

  • The A10W covers an internal dock door or muster point from a standard 86 box with one relay and one alarm input.
  • The station sits in a dedicated call group, so a dock call rings the shipping office and the gatehouse rather than the whole site.
  • Deliveries are logged with the rest of the calls where call detail records are pushed to an external server on port 1809.

How does the site reach people in a power or network failure?

The published behaviour is redundancy plus fallback. Analog lines on FXO ports keep working directly during an internet outage, an outbound SIP call can fall back to an analog line when the trunk fails, and the OM20G can dial out through a 3G/4G USB modem where no wired line exists.

  • The OM1000-UC adds dual hot standby across 3 fixed IP addresses with a 10-second health heartbeat, and ETH1 to ETH2 failover takes about 1.75 seconds.
  • Speakers with offline timed broadcast keep the scheduled messages running on their own if the network drops.
  • Alarm notification can call a nominated number when there is a trunk registration failure, an analog line failure or a SIP attack.

Is a warehouse PA system one system or two?

One, in this design. Speakers, call stations, handsets and radio gateways all register to the same PBX as the office phones, so the site keeps one dial plan, one call-record feed and one fault routine instead of a phone system plus an amplifier rack plus a radio network.

  • The console can be an X210i with 106 DSS keys and a gooseneck microphone, or an A330i with 116 keys and 8 short-circuit inputs for alarm and control signals.
  • Recording runs in G.711 and G.729 where a recording server is part of the design, and radio traffic is recorded separately on the W712.
  • Where the site also runs cameras, terminals support ONVIF and AI camera events can trigger pre-recorded broadcasts.

Cabling, power and network notes

  • Speakers need one network run each with PoE where published: A212 as PoE 8 W / PoE+ 15 W, A201 on PoE, PoE+ or DC, PA2S to IEEE 802.3af and PA3 to PoE/PoE+ with 12–24 V 2 A DC as the alternative.
  • Outdoor positions carry their own ratings: A233 and A513W are IP66, A12V is IP66 and IK10 from −40 °C to 70 °C, and the PA2S gateway runs from −30 °C to 60 °C. Check the mounting position against the published rating rather than assuming a canopy is indoors.
  • Zones are wired as separate runs so each can be addressed and level-adjusted independently; up to 20 multicast zones with prioritisation is the ceiling for the family.
  • Where an old analog speaker line exists, bridge it with PA3 or PA2S rather than replacing it: both publish a 10–30 W mono output that adapts to the input voltage and a line out for an external active speaker.
  • The W712 needs a network drop and a radio feed at the rack; record the radio make, model and channel plan during the survey, since group calls join radios to SIP phones.
  • Relay wiring connects the system to the site: A12V has 2 in / 2 out, A10W 1 in / 1 out with a built-in relay, PA2S 1 in / 1 out with a built-in relay, and the A330i console 8 in / 1 out plus RS-485.
  • Where a phone or a station registers from outside the site network, open the firewall deliberately: SIP signalling on 5060 by default and the RTP range 10010–10266, with each call using an RTP and an RTCP port.

A zone plan for a warehouse, area by area

Typical zone and device plan by area

AreaDeviceZone behaviourWhy this device
Yard and loading bankA233 hornOwn zone, outdoor rated30 W rated output at IP66 for distance and engine noise
Picking aislesA212 wallOne zone per hall or per aisle group15 W class D with talkback so a picker can answer
Packing and shipping officeA201 ceilingOwn zone with a wall handset for callsEven indoor coverage plus two-way voice
Dock doors and gatesA12VExtension in the shipping call groupCamera, 10W speaker and 2 in / 2 out for the barrier
Muster point and internal doorsA10WExtension in the site call group86-box position with one relay and one alarm input
Gatehouse and plant roomsV60G wall handsetExtension with a BLF key for the yardA handset where a desk phone has nowhere to sit
Forklifts and marshalsW611W / W620W handset, or W712 radio gatewayPortable extension with push-to-talkReaches the person rather than the building
Site office and security deskX210i / A330i consolePaging control and answering position106 or 116 DSS keys with group broadcasting

Write the zone plan before the speaker schedule: without it, every announcement becomes site-wide and staff stop listening to any of them.

Radio and telephone on one system

The W712 gateway is the bridge between the radio fleet and the telephone system. It integrates a UHF 400–470 MHz radio module, adopts the SIP standard protocol, and supports one connection of an analog or DMR II digital radio plus one SIP call. Group calls connect radios and SIP phones, and the gateway is documented as compatible with mainstream analog and digital radios and with most mainstream IP PBX platforms.

  • Call recording and call logs cover both radio and SIP traffic, stored on a TF card up to 128 GB or on USB storage.
  • Web deployment and management, with trans-regional communication through DSS speed-dial keys.
  • HD audio with G.722 and Opus on the telephony side, so a radio call into a desk phone is still intelligible.
  • The gateway is one per radio channel; the number of channels needed follows the site talk groups, so record them at survey.

Alarms, unattended positions and records

  • One-key alarm activation, alarm light flashing and simultaneous calling to the management unit are stated for the IP endpoint tier, driven from short-circuit inputs on stations, gateways and consoles.
  • A513W carries relay in and out for a PIR sensor, infrared sensor or strobe light, which is how a lone-worker alarm position is built without a second system.
  • Anti-tamper alarms on the A12V and A11V report to the control centre if a cover is removed, and car parks and yards are named as unattended-site environments in the material.
  • Audio archiving records SIP paging, intercom and calls for online review or download where the paging tier provides it.
  • Call detail records can be pushed to an external server on port 1809, so the site can audit outbound traffic without a separate logger.

Compliance, standards and local requirements

Emergency announcements and the fire interface

Where a public address system also carries emergency announcements, the interface to the fire detection system and the priority of an alarm announcement over a routine one are regulated locally. The published capabilities that matter are up to 20 multicast zones with prioritisation, one-key alarm activation, alarm light flashing and simultaneous calling to the management unit, plus short-circuit inputs on consoles and gateways. Have the fire interface designed and signed off by the site fire contractor — it is not a feature that can be bolted on after handover, and this page makes no certification claim.

Hearing protection, noise and announcement levels

In a working warehouse the announcement has to be intelligible above machinery and vehicle movement, and the people hearing it are often wearing hearing protection. The material supports the design with rated output figures (A233 30 W, A212 up to 15 W class D, FH-S01 up to 20 W, A513W up to 10 W on DC), environmental noise detection, self-test and monitoring on the speaker range, and remote volume adjustment per device. Mounting heights, the measured ambient level and the hearing-protection policy are site matters; confirm them with the site safety officer before positions are fixed.

Cabling, PoE and outdoor ratings

Speakers and gateways are PoE devices, so the switch budget has to cover them: PA2S is IEEE 802.3af, PA3 is PoE/PoE+ (IEEE 802.3at, published as PoE Class 4) with 12–24 V 2 A DC as the alternative, A212 is published as PoE 8 W / PoE+ 15 W, and A201 takes PoE, PoE+ or DC. Outdoor positions must match the site: the A233 horn and the A513W video speaker are IP66, the A12V is IP66 and IK10 from −40 °C to 70 °C, and the PA2S gateway runs from −30 °C to 60 °C. Cable classes, separation from power and containment rules are local — confirm them before first fix.

Radio use, recording and local rules

The W712 puts UHF 400–470 MHz radios on the telephone system, and radio spectrum use, licence conditions and permitted power are regulated nationally — the site own radio licence and its conditions apply. Recording is a second question: audio archiving of SIP paging, intercom and calls is published for the paging tier, and the W712 records radio and SIP calls to TF or USB storage. What may be recorded, how long it is kept and what the workforce is told are local determinations. Confirm both with the site own compliance owner before the gateway is installed.

Standards referenced

Frequently asked questions

Can we page the yard without disturbing the offices?

Yes. Zones are addressed independently, the family supports up to 20 multicast zones with prioritisation, and the advanced tier adds dynamic zone control and remote volume adjustment. A233 covers the yard at 30 W and IP66; office zones use A201 or A212.

Do we have to throw away the analog paging line?

No. The IP endpoint tier is stated to bridge legacy paging systems into the IP environment, and the PA3 and PA2S gateways drive passive speakers and legacy analog horn speakers with a 10–30 W mono output and a line out for an external amplifier.

How do we connect the forklift radios?

With the W712 RoIP gateway: a UHF 400–470 MHz radio module, one analog or DMR II radio plus one SIP call, group calls between radios and SIP phones, and recording to a TF card up to 128 GB.

Can drivers or pickers take a call away from a desk?

Yes. The W611W is IP67 with 16 DSS keys and a push-to-talk key, a 1900 mAh battery and up to 9 h talk; the W620W has a 3000 mAh battery with up to 13 h talk, dual microphones and H.264 video preview. Both are Wi-Fi 6 dual-band.

How loud is a horn speaker, and how many do we need?

The A233 is published at 30 W rated output with IP66 protection and a built-in microphone for self-test, monitoring and environmental noise detection. Position count follows the zone plan and the measured ambient level, so it is fixed at survey rather than from a rule of thumb.

How does the intercom system handle a power cut?

Analog lines on FXO ports keep working directly, an outbound SIP call can fall back to an analog line when the trunk fails, and the OM20G can dial out through a 3G/4G USB modem. The OM1000-UC adds dual hot standby with 3 fixed IP addresses and a 10-second heartbeat.

Where do the speakers get their power?

Over the network cable where PoE is published: A212 as PoE 8 W / PoE+ 15 W, A201 on PoE, PoE+ or DC, PA2S to IEEE 802.3af and PA3 to PoE/PoE+ with 12–24 V 2 A DC as an alternative. Budget PoE per switch before ordering the speaker schedule.

Project evidence

We have not published a named reference project on this page. The site does not carry customer names or installation records until the client confirms in writing which projects may be made public.

Page author: NEXVIA EngineeringPublished:Last updated:

Covers: warehouse intercom · warehouse pa system · warehouse intercom system · warehouse public address system · warehouse paging pa sound system

All IP telephony, intercom and paging equipment in this design is supplied and integrated by NEXVIA.

Already decided on a platform, or replacing a system?

Explore Products

Related products

Planning an IP telephony project?

Send us the site type, the number of extensions or rooms and the areas to cover — we will come back with a configuration and quotation.

Send the site details

Six facts build a configuration: site type, extensions or rooms, simultaneous calls, areas to cover, existing lines and the documents you already hold. Send as many as you know — nothing has to be final before the first reply.

  • Reply within one working day
  • Configuration + quotation for your site
  • Your details are used only to answer this inquiry

* required