Skip to content

Care console · nurse station

A320i nurse console phone — ward station, 20 SIP lines, up to 100 devices

The console the care deck puts at the nurse station: a 10.1-inch Android touchscreen that takes the ward calls, colour-codes and prioritises them, pushes the room number to the corridor display and keeps the call and attendance logs.

  • 10.1-inch 1280×800 touchscreen running Android 9.0 — one source prints 10-inch
  • 20 SIP lines and up to 116 DSS keys; up to 100 devices can be connected to one console
  • Emergency calls need a password before the call is connected, so a real person answers
  • Prioritised, colour-coded calls with call and attendance logs, plus push to the corridor display and broadcasting and access control from the same screen
  • 92 dB full-duplex speaker, gooseneck microphone, 8 MP camera with a privacy cover
  • Extensions can be configured centrally from the Device Link App over Bluetooth
A320i nurse console phone with a 10.1-inch touchscreen, gooseneck microphone and PTM handset

From pull cord to nurse station

The call starts at the bedside or in the bathroom and ends at this console. In the deck flow, the room terminal raises the call, the console shows it as a prioritised, colour-coded entry, and the same event is repeated in the corridor so staff outside the room see it.

  • Incoming calls are amplified through ceiling or wall speakers, so they are heard away from the desk
  • Call type is carried by colour and flashing pattern: slow flash for staff presence and staff assist call, quick flash for toilet emergency call and code blue
  • The console pushes notification of the call status and location to the corridor display
  • A password is required before an emergency call is connected
  • When the station is unattended, calls can be transferred to a portable Wi-Fi handset
  • Call and nurse attendance logs stay available for record tracing

The corridor light over the room door is powered and controlled by the bedside intercom, separately from the console.

How many rooms one console serves

The deck sizes the console against whole wards rather than against a phone count: one console is proposed for a 70-bedroom nursing home and one for a 50-bedroom clinic plan. The guide also states that up to 100 devices can be connected to the console.

The two care configurations proposed in the deck

SiteCall points proposedConsoleAlso proposed
Nursing home — 70 bedrooms, 40 rooms70 bedside stations (Y501W/Y501W-Y); 70 KT30/KT31 bathroom buttons1 × A320i40 CL-01 corridor lights (optional); 4 CMD-01 per floor (optional); 15–20 portable handsets
Small hospital / clinic — 50 bedrooms, 15 rooms50 bedside stations (Y501W-Y); 15 door-side stations (Y501W); 15 KT30/KT31 buttons1 × A320i15 CL-01 (optional); 2 CMD-01 per floor (optional); 15–20 portable handsets

These are the proposals printed in the deck, not a limit. Send us the room count and shift pattern and we will size the console and the call points together.

An operator position, not a desk phone

On the desk the console is an Android device with an operator interface: keys to route and monitor, logs to answer from, and the same screen driving the speakers and the door.

  • Up to 116 DSS keys, each settable as line, BLF or speech dial
  • Broadcasting and access control from the console, including remote door unlocking during an intercom call
  • Languages: Chinese, English, Spanish, Russian and Korean
  • Local phonebook of 2000 entries and a 1000-entry call log
  • 10-way audio conference and 3-way video conference
  • Install angle 40°–50°, EHS headset support, PTM handset with a PTT option
  • Colours: gunmetal grey and white
  • The deck states that terminals used with the console can be scanned and provisioned automatically

Where it fits on site

Nurse station of a care home

One console against a whole floor plan: calls answered, colour-coded, logged and repeated to the corridor display.

Clinic reception and dispatch

Room calls, broadcasting and door release from the same position, with the logs kept for record tracing.

Monitoring and dispatch point

The console is documented as the monitoring centre or host position for dispatching management in small and medium sites.

Specifications

Console

Screen10.1-inch, 1280×800 (one source prints 10-inch)
Operating systemAndroid 9.0
SIP lines20
DSS keysUp to 116
SpeakerUp to 92 dB, full duplex
MicrophoneGooseneck
HandsetPTM; standard or PTT handset optional
Conference10-way audio, 3-way video
Camera8 MP adjustable, with privacy cover
VideoH.264

Care functions

Connected devicesUp to 100
Emergency callPassword required before the call is connected
Call handlingPrioritised calls with colour coding; customisable call types
LogsCall and attendance logs, viewable and exportable
Corridor displayPush notification of call status and location
PagingBroadcasting supported from the console
Access controlSupported, including remote door unlocking during an intercom call
LanguagesChinese, English, Spanish, Russian, Korean
DeploymentDevice Link App; extensions configured centrally over Bluetooth

Network & power

EthernetDual gigabit (10/100/1000 Mbps)
PoEIntegrated
Wi-Fi2.4 GHz and 5 GHz
Bluetooth5.0
Install angle40°–50°
EHS headsetSupported

iSpecifications are taken from the care solution deck, the product guide and the console documentation. The screen is printed as 10-inch in one deck and 10.1-inch (1280×800) in the others — confirm the panel on the quotation. Dimensions, weight and IP rating are not stated.

Choosing between options

ModelSpecifications
KT10433 MHz · 6–25 m range · Self-powered, no battery · Up to 10 per station
KT30IP65 · 2 m pull cord · 433 MHz · 6–25 m range
KT31IP44 · 2 m pull cord · No power needed · Y501 series host
X3053.5" 320×240 screen · Braille digit keys · 4 speed-dial keys · Dual gigabit + PoE
X3063.5" 320×240 LCD · Wi-Fi 6 dual-band · Bluetooth 5.0 · Braille digit keys
A308i7" 1024×600 · 20 SIP lines · 116 DSS keys · 90 dB speaker
A320i10.1" touchscreen · 20 SIP lines · 116 DSS keys · Up to 100 devices
A330iAndroid 14 · 10.1" touchscreen · 116 DSS keys · 8 in / 1 out + RS-485
A3087" 1024×600 · 5 MP camera · Android 9.0 · Gigabit port

Compatibility boundaries

This model uses standard SIP and the interfaces listed in the specification table. Confirm the PBX, SIP provider or platform against those interface notes before the order; where the documentation does not state a value, the table records it as not stated rather than estimating. PoE, analog port variants, power options and card compatibility are fixed at order time.

Handover, spares and support

Extension plan, provisioning and interface language can be prepared before dispatch. Remote support continues after handover. Spare-part, warranty and service terms are confirmed in the quotation for the models and quantity ordered, so they are not printed as a single figure here.

Where it sits in the system

Frequently asked questions

How many beds can one console serve?

The deck proposes one A320i for its 70-bedroom nursing-home plan and one for its 50-bedroom clinic plan, and the guide states that up to 100 devices can be connected to the console. Both are useful planning figures — send us your room count and shift pattern and we will size it for the site.

Why does an emergency call need a password?

It is a deliberate rule in the source material: the recipient enters a password before the call is connected, so the call is answered by a real person rather than falling through.

Can the console show what has happened during a shift?

Yes. Call and nurse attendance logs are viewable and can be exported, which the deck presents as record tracing.

Does it also do paging and door release?

Both are stated: broadcasting from the console, and access control including remote door unlocking during an intercom call. The console is also documented as able to scan and provision the terminals used with it.

Standards referenced

Explore Products

Related products

Planning an IP telephony project?

Send us the site type, the number of extensions or rooms and the areas to cover — we will come back with a configuration and quotation.

Send the site details

Six facts build a configuration: site type, extensions or rooms, simultaneous calls, areas to cover, existing lines and the documents you already hold. Send as many as you know — nothing has to be final before the first reply.

  • Reply within one working day
  • Configuration + quotation for your site
  • Your details are used only to answer this inquiry