IP PBX · enterprise
OM200G IP PBX — hot-swap cards, 96 analog ports, 496 SIP trunks
Four card slots at 24 lines each give up to 96 analog ports, with hot-swappable cards and gigabit Ethernet. This is the model that scales with the site rather than being sized to it.
- Four card slots of 24 lines — up to 96 analog ports in one chassis
- Cards are hot-swappable, so a failed card is replaced without taking the site down
- 496 SIP trunks with up to 120 concurrent calls each
- Two gigabit Ethernet ports, up from 100M on the smaller models
- Optional PT2400 and PT4800 patch panels for structured cabling
- Choice of single AC, dual AC, single DC or dual DC power

Card options and port combinations
The four slots accept voice interface cards in several mixes, so the analog port count is decided by the cards fitted rather than by the model number alone.
OM200G card combinations
| Card | FXS | FXO |
|---|---|---|
| 24FXS | 24 | 0 |
| 24FXO | 0 | 24 |
| 16FXS + 8FXO | 16 | 8 |
| 12FXS + 12FXO | 12 | 12 |
Each card presents six RJ45 sockets per group, broken out to telephone pairs. Patch panel options take the cabling into a structured frame.
Gigabit networking
The OM200G and OM1000-UC are the two models in the range with gigabit Ethernet; the OM20G, OM50G and OM80E are 100M.
- ETH1 and ETH2 share a single IP address, default 192.168.2.240
- ETH2 can be set as a redundant port — it takes over from ETH1 in about 1.75 seconds
- Alternatively ETH2 works as an internal connection port with its own IP address, or as a dedicated SIP trunk interface
Four power configurations
The model spans single AC, dual AC, single DC and dual DC. Dual supplies are the usual choice for a site where an outage is not acceptable.
Product gallery

Where it fits on site
Campus or large office
Ninety-six analog ports in one chassis, with cards added as floors are fitted out.
Hotel with structured cabling
Patch panels take several hundred room lines into a single frame.
Site that cannot go offline
Hot-swap cards and dual power supplies keep calls running through a fault.
Specifications
Capacity
| Card slots | 4 (SLOT1–SLOT4), 24 lines per card |
|---|---|
| Analog ports | Up to 96, determined by the cards fitted |
| Maximum SIP trunks | 496 |
| Concurrent calls per trunk | 120 |
| Ring group members | Up to 60 extensions |
| Extension numbering | Starts at 200 |
Interfaces & storage
| Ethernet | 2 × gigabit (ETH1 + ETH2), one shared IP address |
|---|---|
| Default IP | Static 192.168.2.240 |
| Internal storage | 16 GB |
| Patch panel options | PT2400, PT4800 |
| Power options | Single AC / dual AC / single DC / dual DC |
| Console | CON, RJ45 to RS232 |
Features & management
| Hot-swap cards | Yes |
|---|---|
| Recording | Remote only |
| Dual hot standby | No |
| DID/DOD | Not covered in the manual for this model |
| Port capture | Supported, up to 200 seconds |
| Initial admin password | admin |
iSpecifications are taken from the OM series product manual. Card and power configuration are confirmed on the quotation.
Choosing between options
| Model | Specifications |
|---|---|
| OM20G | Up to 4 analog ports · 24 SIP trunks · 16 GB storage · 3G/4G USB modem |
| OM50G | Up to 12 analog ports · 62 SIP trunks · Local + remote recording · OpenVPN client |
| OM80E | Up to 48 analog ports · 216 SIP trunks · AC 100–240 V or −48 V DC · Remote recording |
| OM200G | 4 hot-swap slots · Up to 96 analog ports · 496 SIP trunks · 2 × gigabit Ethernet |
| OM1000-UC | 1000 SIP trunks · 4 × gigabit interfaces · Dual hot standby · DID/DOD support |
Compatibility boundaries
This model uses standard SIP and the interfaces listed in the specification table. Confirm the PBX, SIP provider or platform against those interface notes before the order; where the documentation does not state a value, the table records it as not stated rather than estimating. PoE, analog port variants, power options and card compatibility are fixed at order time.
Handover, spares and support
Extension plan, provisioning and interface language can be prepared before dispatch. Remote support continues after handover. Spare-part, warranty and service terms are confirmed in the quotation for the models and quantity ordered, so they are not printed as a single figure here.
Where it sits in the system
Frequently asked questions
Do I have to choose the card mix up front?
How is this different from the OM80E?
Can it act as a pure SIP system?
Does it support DID/DOD?
Standards referenced
Explore Products
Related products
Planning an IP telephony project?
Send us the site type, the number of extensions or rooms and the areas to cover — we will come back with a configuration and quotation.
Send the site details
Six facts build a configuration: site type, extensions or rooms, simultaneous calls, areas to cover, existing lines and the documents you already hold. Send as many as you know — nothing has to be final before the first reply.
- Reply within one working day
- Configuration + quotation for your site
- Your details are used only to answer this inquiry
Page author: NEXVIA EngineeringPublished: Last updated: