Skip to content

Reference configuration · Clinic and small hospital

50-bed clinic — reference configuration

The 50-bed plan from the care material, written as an equipment list: 50 bedside stations, 15 door-side stations, a pull cord in every room, one nurse console and 20 portable handsets — plus the SIP core and the desk phones that the ward plan does not cover.

  • Rooms: 15 — ten four-bed rooms and five two-bed rooms, 50 beds in all
  • Bedside stations: 50 × Y501W-Y, one per bed
  • Door-side stations: 15 × Y501W, one per room, for staff emergency and code blue calls
  • Bathroom call points: 15 × KT30 or KT31, one per room
  • Nurse console: one A320i, with call and attendance logs
  • Extensions in this plan: 100 SIP, inside an OM80E’s 216 SIP trunks
Care workflow with a call raised at the bedside and answered at the nurse station

This is a reference design prepared from the product datasheets, not a record of a named customer installation.

Design parameters — what should you know?

Beds
50 — 10 four-bed rooms and 5 two-bed rooms
Rooms
15
Bedside / door-side stations
50 / 15
Bathroom call points
15 — KT30 wireless or KT31 wired
Shift pattern
Three shifts: 08:00–16:00, 16:00–24:00, 00:00–08:00
SIP extensions
100 — ward terminals, console, handsets and desk phones

Equipment list for this design — what should you know?

ItemModelQtyNote
Bedside stationY501W-Y50One per bed, handset version: nurse call, staff assist call, presence and code blue; connects a KT30 or KT31 call point and drives the corridor light
Door-side stationY501W15One per room at the door: staff emergency call, code blue call and presence
Nurse consoleA320i110.1-inch touch screen, 20 SIP lines, up to 116 DSS keys; prioritised colour-coded calls, call and attendance logs, broadcast and access control from the same screen
Bathroom call pointKT30 / KT3115One per room: KT30 wireless (IP65, 433 MHz) where no cable reaches the bathroom, KT31 wired (IP44, 2 m pull cord) where one does
Corridor lightCL-0115One above each room door; powered and controlled by the bedside station, indicating call status in red, green, blue and yellow
Corridor displayCMD-012One per floor in public corridors, optional in the printed plan; up to 30 prioritised messages on a 128×32 dot-matrix display
Portable Wi-Fi handsetW611W20Calls transfer to a handset when the nurse station is unattended; 2.4-inch screen, up to 16 DSS keys
Desk phoneX303G14Reception, duty room, pharmacy, admin and consulting rooms; four SIP lines, dual gigabit ports, PoE
IP PBXOM80E-8S/81216 SIP trunks for the 100 extensions in this plan; eight FXS and eight FXO ports; AC 100–240 V or −48 V DC
Ward speaker (optional)FH-S012Optional addition, not in the printed plan; ceiling speaker that amplifies incoming calls where they must be heard away from the console; PoE IEEE 802.3af
PoE access switchCustomer network hardware624-port units sized to the ward stations, desk phones and network positions across the ward

The room, position by position — what should you know?

The care plan places a station wherever a call can start. The bedside position is for the patient, the door-side position is for the staff, and the bathroom gets a pull cord because a call there has to be reachable from floor level.

The printed 50-bed clinic plan

PositionDeviceQtyCall types
BedsideY501W-Y50Nurse call, staff assist call, presence, code blue
Door sideY501W15Staff emergency call, code blue, presence
BathroomKT30 or KT3115Toilet / bathroom emergency call
Corridor, at the doorCL-0115Status only — red, green, blue and yellow
Corridor, public areaCMD-012Call info, type and location; optional in the plan
On the moveW611W / W620W15–20Calls transferred when the station is unattended

This is a reference design prepared from the product datasheets, not a record of a named customer installation.

How a call is raised and escalated — what should you know?

  • A press at the bed, the door or the pull cord raises the call on its host station
  • The console shows it as a prioritised, colour-coded entry, and a real person has to enter a password before an emergency call is connected
  • The same call is repeated outside the room: the corridor light over the door and, in public corridors, the display
  • Slow flash marks staff presence and staff assist calls; quick flash marks a toilet emergency call and code blue
  • When the nurse station is unattended, calls can be transferred to the portable handset
  • Call and nurse attendance logs remain available for record tracing

One A320i is proposed for the whole 50-bed plan; the guide states up to 100 devices can be connected to a console, and this plan uses 65 ward stations plus the call points and displays.

The SIP core behind the ward — what should you know?

The ward terminals and the clinic’s ordinary phones register on the same SIP network, so one PBX carries both. The OM80E’s 216 SIP trunks hold the 100 extensions in this plan with room for the next ward.

  • Eight FXS and eight FXO ports in the 8S/8 variant: the clinic’s fax, lift and alarm lines can stay analog
  • Fax runs as T.38 or G.711 pass-through; over an analog line, G.711 pass-through is required
  • Recording on this model is remote only, to a recording server (default port 1311)
  • Broadcasting to analog extensions is supported; two-way broadcast is not supported by the series
  • Analog line dialling delay on the OM80E defaults to 600

Frequently asked questions

How many devices can one nurse console take?

The care guide states that up to 100 devices can be connected to the console. This plan puts 65 ward stations (50 bedside and 15 door-side) plus 15 pull cords and two corridor displays on it, which is inside that figure. Send us the room and bed count and we will confirm the console count against your own ward layout.

Why 50 bedside stations but only 15 bathroom buttons?

Because there is one bathroom per room, not one per bed. The plan puts a station at every bed (50) and a single KT30 or KT31 call point in each of the 15 rooms, with the corridor light also counted once per room.

Do the care terminals share the clinic phone system?

Yes. The ward stations, console and desk phones all register as SIP extensions on the same PBX, and the OM80E’s 216 trunks and 100 extensions leave room for the next ward. Keep the care extensions in a separate number range from the office phones so the ward and the front desk stay easy to read.

What happens to the clinic’s existing lines?

They stay. The 8S/8 variant of the OM80E gives eight FXO ports, so the fax, lift and alarm lines remain analog, and analog extensions can be wired where a device only has a phone socket. Fax is set as T.38 or G.711 pass-through; over an analog line, G.711 pass-through is the required mode.

Explore Products

Related products

Planning an IP telephony project?

Send us the site type, the number of extensions or rooms and the areas to cover — we will come back with a configuration and quotation.

Send the site details

Six facts build a configuration: site type, extensions or rooms, simultaneous calls, areas to cover, existing lines and the documents you already hold. Send as many as you know — nothing has to be final before the first reply.

  • Reply within one working day
  • Configuration + quotation for your site
  • Your details are used only to answer this inquiry

* required

Page author: NEXVIA EngineeringPublished: Last updated: